Convo Inverter Cvf-s1 Manual Now

Adjusting these settings allows you to customize how the drive starts, stops, and receives frequency signals. F0.02 (Running Command): 0: Panel running command (use the buttons on the VFD). 1: Terminal running command (external switch). F0.03 (Frequency Setting): 0: Panel potentiometer input. 1: Digital set (Up/Down buttons on panel). 3: AVI analog input ( 5: ACI current input (

0: Potentiometer; 1: Panel buttons; 3: AVI (0-10V); 5: ACI (4-20mA) F0.04 Max Input Frequency Standard is 50.0 Hz; adjustable up to 999 Hz F0.05 Upper Limit Frequency Sets the maximum allowable running frequency F2.13 – F2.17 Digital Input Settings Convo Inverter Cvf-s1 Manual

4.2 Control Terminals (Low Voltage)

| Terminal | Signal | Description | |----------|----------------------|----------------------------------| | +10V | Reference output | +10V DC / 10mA max | | VI | Analog input | 0–10V (default frequency ref) | | CI | Analog input | 0–10V or 4–20mA (jumper set) | | GND | Common for analog | | | FWD | Run forward | Close to COM to run | | REV | Run reverse | Close to COM to run reverse | | D1, D2 | Digital inputs | Multi-function (preset speeds) | | COM | Digital common | | | AO | Analog output | 0–10V (e.g. output frequency) | | RA, RB, RC | Relay output | Form C (250VAC / 1A) – fault or run | Adjusting these settings allows you to customize how